Matters needing attention in installation of Gas-fired BoilerGas-fired boiler also says that gas-fired heating boiler is a kind of boiler which uses gas combustion to heat water to satisfy people's heating. It belongs to the category of domestic boiler. By gas-fired heating boiler we usually refer to gas-fired atmospheric hot water boiler, gas including natural gas, liquefied gas, city gas, coke oven gas, biogas and so on. There are explosion-proof doors on the rear of the fuel-fired boiler or on the smoke pipe, and the position of the explosion-proof doors should be conducive to the discharge of the explosion. In cases where explosive gas may endanger the safety of operators, a pressure relief guide tube shall be installed on the explosion-proof door. The installation of boilers, auxiliary machines and water treatment equipment shall be in accordance with the technical requirements of the equipment manufacturing plant. . The equipment foundation must wait until the equipment arrives and checks correctly with the design drawing before construction. 3. When installing the equipment, avoid the equipment, and the installation material should be stacked on the floor. When using building column, beam lifting equipment, the bearing capacity of beam and column must be verified in advance. 4. After installation of oil, gas, hot water and steam pipes, the pressure test acceptance shall be carried out according to the Code for Construction and acceptance of Industrial Metal Piping Engineering GB 50235 / 1997.
Due to increase market demand for air conditioning, we increased the number of production lines, faced with the urgent need of a szs oil horizontal steam boiler szs8 1 25 y q a problems. Emergence of fast boiler is time for us to solve this problem. From the start of contract manufacturing to transportation to our company for installation and operation, Fang fast only 35 days to solve our urgent needs. --customer feedback
Water produced by the following factors: the temperature of the flue gas (91% in order to achieve thermal efficiency, the temperature of the flue gas needed to reach 170 ℃), where the total surface area of the heat chimney, chimney and chimney material. Maintenance of the burner. Electric szs oil horizontal steam boiler szs8 1 25 y q a and burner maintenance, repair after steam supply. Because the products of combustion will corrode the boiler, clean up carbon deposits, therefore, not allow the products of combustion in the boiler memory stay too long. 3, clean electric boiler essential content.
Steam boiler overpressure phenomenon and treatment of szs oil horizontal steam boiler szs8 1 25 y q as refers to water heated to a certain temperature parameters and the production of industrial steam boiler, the water in the steam drum is heated to become vapor, fire emits heat in the furnace, it is the principle of the steam boiler. Steam boiler belongs to special equipment, design, processing, manufacturing, installation and use of the boiler must be supervised by technical supervision departments, users only get to use the boiler permits to use steam boilers. The fuel steam boiler (electricity, oil, gas) can be divided into an electrical steam boiler, steam boiler fuel, gas steam boiler three kinds; constructed according to the steam boiler can be divided into vertical, horizontal steam boiler, steam boiler mostly small and medium sized single , double the return of the vertical structure, large steam boilers and more horizontal structure of three return. Steam boilers and boiler overpressure phenomenon processing method, the phenomenon of over-pressure boiler steam pressure ⑴ sharp rise exceeds the allowable operating pressure, the safety valve pressure gauge pointer over the red line pressure is still elevated. When the interlock ⑵ overpressure protection device operation, overpressure alarm should be issued to stop the air blowing, the wind, coal. ⑶ steam temperature rises and steam flow. 2, boiler overpressure treatment ⑴ weakened rapidly burning, manually open the valve or bleed valve. ⑵ increase the water supply, while strengthening the lower drum sewage (you should pay attention to maintaining normal water level boilers), to reduce the boiler water temperature, thereby reducing the pressure drum boilers. ⑶ safety valve pressure gauge malfunction or all of the damage, emergency shutdown, safety valves and pressure gauges are to be repaired after the boost operation. When ⑷ endanger the safe operation of the boiler overpressure occurs, the buck should take measures, but too fast buck is strictly prohibited. The ⑸ serious boiler overpressure eliminate, to the shutdown of the boiler internal and external inspection, to eliminate the overpressure caused by deformation, leakage and other safety accessories and maintenance unqualified.
IPS18 S8AO48/M12plug for ventilator output 92.HD1K-015GK010AABB Y580976918248-150/1ABAUMER Enidine UC 4858 / OEM1.25 .SICK UE 48-3S
Get A Quote
Get A Quote